Section 20: Recommendations: Difference between revisions
From ICAR Wiki
(Created page with "The most important question: what method to use if you need to measure CH4? The answer may be: it depends on what you like to do. In the Table 7 we summarize some experimental conditions and designs, and make recommendations. {| class="wikitable" |+ !Experimental condition and design !Methane measurement method recommendation |- |Need to measure absolute methane values – animal numbers and location not important |Respiration chamber; SF6; GreenFeed |- |Need to rank ani...") |
No edit summary |
||
| Line 1: | Line 1: | ||
The most important question: what method to use if you need to measure | The most important question: what method to use if you need to measure CH<sub>4</sub>? The answer may be: it depends on what you like to do. In the Table 7 we summarize some experimental conditions and designs, and make recommendations. | ||
{| class="wikitable" | {| class="wikitable" | ||
|+ | |+ | ||
Revision as of 14:02, 6 March 2024
The most important question: what method to use if you need to measure CH4? The answer may be: it depends on what you like to do. In the Table 7 we summarize some experimental conditions and designs, and make recommendations.
| Experimental condition and design | Methane measurement method recommendation |
|---|---|
| Need to measure absolute methane values – animal numbers and location not important | Respiration chamber;
SF6; GreenFeed |
| Need to rank animals from low to high methane emission | Sniffer method |
| Need to measure methane on farm | Sniffer method;
GreenFeed; PAC |
| Low budget measurements needed | Proxy;
Proxies measurement |
| High animal numbers required | Sniffer method;
Proxies measurement; LMD |
Table 7. Recommendations for measuring methane in diverse experimental conditions and designs.